LIGHT · DATA · DESIGN

Technical guide

The parameters that define the quality of light and how to choose them for each space. Indicative values: check the individual product sheet for every project.

Colour temperature (K)

The tone of white light, in kelvin. The lower the value, the warmer the light.

ValueToneRecommended use
2700 KWarm whiteLiving room, bedroom, restaurant, hotel
3000 KWarm-neutral whiteKitchen, bathroom, corridors, homes in general
3500 KNeutral whiteShops, showrooms
4000 KNeutral-cool whiteOffices, workshops, car parks, facades
Dim-to-warm 1500–2700 KGets warmer as it dims, like an incandescent lamp or a candleLiving room, bedroom, restaurant, hotel, evening scenes
Tunable white 2700–6000 KAdjustable from warm white to cool whiteHuman Centric Lighting, offices, schools, smart homes
  • Dim-to-warm — at full output the light is about 2700 K; as it dims it gradually falls to about 1500 K, an amber tone close to a flame. One control channel: the dimmer sets intensity and colour together.
  • Tunable white — two sets of LEDs (warm and cool) mixed by the driver: colour temperature is set between about 2700 and 6000 K independently of intensity. It needs two control channels (e.g. DALI DT8, dual 0/1–10 V, Bluetooth/ZigBee). It is the basis of Human Centric Lighting.

Human Centric Lighting (HCL)

Light that follows the natural rhythm of the day. Beyond letting us see, light sets the body clock: ipRGC cells in the retina, most sensitive to blue light (around 480 nm), tell the brain whether it is day or night and influence melatonin, sleep, alertness and mood.

TimeColour temperatureIntensityEffect
Morning, 6:00–9:003500 → 5000 KRisingGentle waking, activation
Day, 9:00–15:005000–6000 KMaximumConcentration and alertness, close to skylight
Afternoon, 15:00–18:004000 KFallingWork without fatigue
Evening, 18:00–21:002700–3000 KReducedRelaxation, melatonin can rise
Night, after 21:001800–2200 KMinimal, low lightSleep; orientation light for corridors and bathroom
  • How it is done: tunable white fittings, two-channel drivers and a system that changes colour temperature and intensity automatically through the day — DALI DT8 (Tc), KNX with an astronomical clock, or Bluetooth/ZigBee control from an app.
  • Light from above, diffused: the biological effect depends on light reaching the eyes (vertically), not only on the desk. Panels, linear lights and indirect light on the ceiling work better than narrow spots.
  • Where: offices and meeting rooms, schools, hospitals and care homes, hotels, smart homes — especially spaces with little daylight.
  • References: CIE S 026 (melanopic EDI), DIN SPEC 67600, WELL Building Standard (circadian lighting). The values in the table are indicative: the profile is adapted to season, latitude and the habits of the people in the space.

Colour rendering (CRI / Ra)

How faithfully light shows colours compared with daylight (100).

IndexClassRecommended use
Ra ≥ 80StandardCorridors, plant rooms, outdoors
Ra ≥ 90HighHomes, restaurants, premium offices
Ra ≥ 95Very highArt galleries, fashion and jewellery shops, food

Ingress protection (IP)

The first digit is protection against solids and dust, the second against water (IEC 60529).

RatingProtectionWhere
IP20Dry interiorsLiving room, bedroom, office
IP44Splashing waterBathroom (outside the shower zone), covered porches
IP54Dust and splashesCovered terraces, professional kitchens
IP65Water jetsFacades, garden, shower zone
IP67Temporary immersionIn-ground lights, bollards in flower beds
IP68Continuous immersionPools, fountains

Beam angle

The opening of the light cone. Narrow beams create accents, wide beams light evenly.

AngleTypeUse
10°–15°Very narrow spotSingle objects, small paintings, facade effects
24°SpotAccents, furniture, tables
36°Medium floodGeneral lighting with spots, corridors
50°–60°Wide floodEven light in low rooms
WallwasherAsymmetricEven light on a whole wall

Control and dimming

How light is switched, dimmed and programmed.

SystemHow it worksWhere
On/offSimple switchService rooms
Triac (phase cut)Wall dimmer on the 230 V lineRenovations, single circuits
0/1–10 VSeparate analogue signalOffices, shops
DALI / DALI-2Digital bus, every fitting addressableSmart homes (KNX), hotels, offices
Bluetooth / ZigBee / Wi-FiWireless control from an app or hubHomes without extra wiring

Mounting types

The choice depends on the ceiling and the effect you want.

TypeDescriptionSuitable for
SurfaceFixed directly to ceiling or wallConcrete ceilings, renovations
SuspendedHung from cables or a rodHigh ceilings, tables, islands
RecessedSet into a false ceiling, with trimPlasterboard, quick installation
TrimlessFlush with the plaster, no visible trimMinimal architecture
In-ground / in-wallSet into the floor or wallSteps, paths, facades

Photometric quantities

The units you find on technical sheets.

QuantityMeaningReference
Luminous flux (lm)Total amount of light emittedComparing fittings
Efficacy (lm/W)Light produced per wattEnergy use
Illuminance (lx)Light reaching a surfaceLiving room 100–300 lx, kitchen 300–500 lx, office 500 lx
UGRGlare ratingOffices: UGR < 19
SDCM / MacAdamColour consistency between LEDs≤ 3 for rows of spots

48 V magnetic track

Safety and flexibility of extra-low-voltage systems.

ElementWhat it isDesign note
SELV 48 VSafety extra-low voltageLights moved by hand, no tools
Power supplySeparate, in the false ceiling or panelPower = sum of lights + 20% reserve
Run lengthLimited by voltage dropFeed long runs from several points
ConnectorsL, T, X, flexible, vertical cornersGeometric shapes on ceiling and wall

Care and maintenance

  • Switch off and let the fitting cool before cleaning.
  • Crystal and glass: soft microfibre cloth, no abrasives or ammonia.
  • Metals and brass: dry cloth only.
  • Outdoor fittings: check seals and cable glands once a year.
  • Installation must be carried out by a qualified electrician according to local regulations.